- Support Center
- Error Messages
- Series 2-LHS
Artic Sensor 2 Comms!
Definition
The system has lost communication with the angle sensor mounted on the Fore Boom or Luffer
Notes
Check that there is a Green LED, flashing on the sensor. Check cabling between the Stub Boom Sensor and the sensor fitted on the Fore Boom. Renew cabling or replace sensor.